Home> News> Search for SVLEC for Distribution System
September 08, 2023

Search for SVLEC for Distribution System

Clear field wiring is easy to achieve. A junction box bundles multiple cables into one main cable to the controller. Distribution box is equipped with a status indicator, and the user can observe the signal status at any time. Svlec manufactures three types of junction boxes, M8 Distribution Box, M12 Distribution Box, 7/8 Distribution box and so on.



It plays an important role in connecting the distribution cable or optical cable to the user line part and branching the main line. The junction box can be installed in confined spaces such as bridges, boxes, pipes, cable trenches, etc., without occupying the effective use area of the building, it is easy to install and the main cable does not need to be cut.


(1) Outdoor use area of junction box


Ambient temperature: -55~+55℃; Relative humidity: < 95%; Atmospheric pressure: 70~106kPa


(2) Environment for indoor junction box use


Ambient temperature: -25~+40℃; Relative humidity: < 95%; Atmospheric pressure: 70~106kPa


Multi-port I/0 signal distribution


Make your tool wiring clearer and more convenient


Junction box electrical performance



(1) Insulation resistance


①Under the standard atmospheric conditions of the test, the insulation resistance between any two ends and between any terminal and the metal box should not be less than 5×104MΩ.


②After the conditional test, the insulation resistance between any two ends and between any terminal and the metal box should not be less than 5×103MΩ.



(2) Contact resistance of junction box


①Under the standard atmospheric conditions of the test, the contact resistance between the wire and the terminal should not be greater than 5×10-3Ω.


②After the conditional test, the increase of contact resistance between the wire and the terminal should not be greater than 3×10-3Ω.


(3) Dielectric strength


①Under the standard atmospheric conditions of the test, when an AC RMS value of 500V is applied between any two terminals or between any terminal and the metal enclosure, no breakdown or arcing should occur within 1 minute.


② After the condition test, if the AC RMS value is 500V between any two terminals and between any terminal and the metal box, there should be no breakdown or arcing within 30s.


Our Distribution box are available with plugs and Accessories for this kind of plugs. The length of our metering receptacles can be freely selected, and customized services are supported.


distribution system


Share to:

LET'S GET IN TOUCH

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send